MaxCell® Edge Detectable Features

MaxCell® Edge Detectable fabric innerduct is designed to maximize the capacity of conduits in network infrastructure while preserving space for future network deployments. MaxCell Edge Detectable is designed to create additional pathways in greenfield or occupied conduit specifically for outside plant applications, including long lines; under bridges; road, river and rail borings under streets; and, curb to building entrances.

  • Sewn-in Green 18AWG THHN Solid Copper Wire suitable for direct wired toning equipment and above ground handheld locators
  • Solves cabling issues for conduits, allowing a range of cable sizes
  • Enables overlay of cables in occupied conduits
  • Reduces or eliminates number of conduits required in new construction
  • Melting point of 215°C (almost twice that of HDPE)
  • Halogen-free
  • Resistant to ground chemicals and petroleum products
  • Constructed of PET (Polyethylene Terephthalate) and Nylon 6
  • Patented fabric design may reduce pulling tension by up to 20% over previous MaxCell versions
  • Features color coded, pre-installed 565kg pull tape in each cell* for 75mm, 100mm MaxCell. 32mm, 44mm and 52mm MaxCell have pre-installed 565kg VisTM Glide Rope in each cell.
  • Pre-lubed for lower friction during MaxCell and cable installation**
  • Manufactured in the U.S.A.

Design and fabrication of MaxCell is patent protected.
* Higher tensile strength pull tape and rope options are available for difficult cable installations.
** Additional lubrication is recommended to further decrease friction during cable installation.

MaxCell Detectable
MaxCell Detectable

Product Information

32 mm
PRODUCT # MIN CONDUIT ID CELLS MAX CABLE DIAMETER PER CELL MIN BREAKING TENSILE ELONGATION AT 50KG
MXED32121 28mm 1 Cell 12mm 328kg < 2.0%
MXED32122 30mm 2 Cell 12mm 578kg < 2.0%
MXED32123 30mm 3 Cell 12mm 827kg < 2.0%
  Download 32mm Detectable Data Sheet

44 mm
PRODUCT # MIN CONDUIT ID CELLS MAX CABLE DIAMETER PER CELL MIN BREAKING TENSILE ELONGATION AT 50KG
MXED44181 38mm 1 Cell 18mm 427kg < 2.0%
MXED44182 40mm 2 Cell 18mm 775kg < 2.0%
MXED44183 42mm 3 Cell 18mm 1124kg < 2.0%
MXED44184 44mm 4 Cell 18mm 1551kg < 2.0%
  Download 44mm Detectable Data Sheet

52mm
PRODUCT # MIN CONDUIT ID CELLS MAX CABLE DIAMETER PER CELL MIN BREAKING TENSILE ELONGATION AT 50KG
MXED52221 46mm 1 Cell 22mm 491kg < 2.0%
MXED52222 48mm 2 Cell 22mm 902kg < 2.0%
MXED52223 50mm 3 Cell 22mm 1313kg < 2.0%
MXED52224 52mm 4 Cell 22mm 1804kg < 2.0%
  Download 52mm Detectable Data Sheet

75mm
PRODUCT # MIN CONDUIT ID CELLS MAX CABLE DIAMETER PER CELL
MXED64283 75mm 3 Cell 28mm
  Download 75mm Detectable Data Sheet

100mm
PRODUCT # MIN CONDUIT ID CELLS MAX CABLE DIAMETER PER CELL
MXED86383 100mm 3 Cell 38mm
  Download 100mm Detectable Data Sheet